Actron Air CRE-071AS/URC-071AS 7.1kW Cassette Split System - CRE-071AS
Actron Air CRE-071AS/URC-071AS 7.1kW Cassette Split System - CRE-071AS
Couldn't load pickup availability
Actron Air CRE-071AS/URC-071AS 7.1kW Cassette Split System - CRE-071AS
Actron Air CRE-071AS/URC-071AS 7.1kW Cassette Split System - CRE-071AS
Experience superior climate control with the Actron Air CRE-071AS/URC-071AS 7.1kW Cassette Split System. This robust system offers 7.1kW of cooling and 7.85kW of heating power, perfect for maintaining comfort in any season. With a sleek design and premium wired controller, it seamlessly integrates into any space, providing efficient and reliable performance. Ideal for both residential and commercial applications, this system ensures year-round comfort with advanced inverter technology.
What our Experts Think
- Efficient mid-capacity cassette system: The ActronAir CRE-071AS / URC-071AS is a 7.1 kW reverse-cycle cassette split system, designed for medium-sized rooms, offices, and open-plan residential spaces, delivering balanced heating and cooling performance.
- Strong all-season output: Provides around 7.1 kW cooling and ~7.8 kW heating capacity, making it suitable for maintaining comfort year-round in typical Australian conditions.
- Even 360° air distribution: The 4-way ceiling cassette design spreads airflow in all directions, reducing hot and cold spots and improving overall room comfort consistency.
- Efficient inverter operation: Uses a twin-rotary inverter compressor, adjusting output dynamically to match demand, improving energy efficiency and maintaining stable indoor temperatures.
- Quiet, low-profile ceiling install: The indoor unit is flush-mounted into the ceiling, keeping interiors clean and minimal while maintaining strong airflow coverage.
- Advanced usability features: Includes independent louvre control, adjustable fan speeds, self-diagnostics, and drain pump integration, improving installation flexibility and long-term reliability.
- Built for harsh climates: Designed to operate in extreme outdoor conditions (up to ~50°C cooling and down to -25°C heating), ensuring year-round performance stability.
Q&A
Q1: What is the cooling and heating capacity?
A: It delivers 7.1 kW cooling and about 7.85 kW heating, making it suitable for medium to large rooms or open-plan spaces.
Q2: What type of system is this?
A: It is a 4-way ceiling cassette split system, with an indoor cassette (CRE-071AS) and an outdoor inverter unit (URC-071AS) for discreet ceiling installation.
Q3: What room size is it suitable for?
A: Typically suitable for large bedrooms, lounges, offices, or open areas around ~30–65 m², depending on insulation and climate conditions.
Q4: Is it energy efficient?
A: Yes, it uses inverter twin-rotary technology with efficiency around EER ~3.3–3.5 and COP ~3.4–3.7, helping reduce running costs.
Q5: What refrigerant does it use?
A: It uses R410A refrigerant, designed for stable cooling and heating performance in Australian conditions.
Q6: Does it provide good air distribution?
A: Yes, the cassette design offers 360° airflow with independent louvre control, helping distribute air evenly across the entire room.
Q7: Is it quiet during operation?
A: Yes, indoor noise levels typically range from ~40–47 dBA depending on fan speed, suitable for living and workspaces.
Maintenance Tips
- Clean filters every 2–4 weeks (critical): Maintains strong airflow for 7.1 kW cooling and prevents efficiency loss or coil icing.
- Clean indoor cassette coils yearly: Prevents dust buildup, odor issues, and reduced 360° airflow performance.
- Check condensate drain & pump regularly: This system includes a drain pump—keep it clear to avoid leaks or ceiling damage.
- Inspect outdoor unit coil 6–12 monthly: Keeps inverter compressor efficient and prevents overheating in high ambient temps.
- Maintain 360° airflow clearance indoors: Do not block cassette discharge panels for balanced room temperature control.
- Keep outdoor unit clear (≥30–50 cm space): Ensures proper heat exchange and stable performance in extreme weather.
- Check refrigerant lines annually: Look for insulation wear or leaks to avoid reduced cooling/heating capacity.
- Tighten electrical connections during service: Helps prevent faults and ensures stable operation under ~17.5A full load conditions.
- Run seasonal test (summer/winter): Early detection of fan, sensor, or control issues before peak usage periods.
- Annual professional HVAC service: Required for refrigerant handling, deep cleaning, and full system diagnostics.