Goodman - 1.5 Ton/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 13.4 SEER2 - R32 - GLXS3BN1810 / CHPTA2426B3 / GCVC960603BN
Goodman - 1.5 Ton/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 13.4 SEER2 - R32 - GLXS3BN1810 / CHPTA2426B3 / GCVC960603BN
Couldn't load pickup availability
Goodman - 1.5 Ton/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 13.4 SEER2 - R32 - GLXS3BN1810 / CHPTA2426B3 / GCVC960603BN
Goodman - 1.5 Ton/60,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 13.4 SEER2 - R32 - GLXS3BN1810 / CHPTA2426B3 / GCVC960603BN
A Goodman Gas Furnace and Air Conditioner System is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, a Goodman Gas Furnace and Air Conditioner System is the perfect choice for all of your heating and cooling needs.
Features
- Ideal size to cover a medium-sized house
- 1.5 ton, 13.4 SEER2 AC-only condenser
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Low sound output
- Fully charged for up to 15' of line set
- Factory-installed filter drier
- 2 ton horizontal evaporator coil
- Can be used with heat pump and AC-only condensers
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
- Factory-installed TXV kit
- This furnace is ideal to heat a medium-sized house (in average climate conditions)
- 60,000 BTU 96% AFUE two stage variable speed natural gas furnace
- Requires plastic/PVC flue venting
- Can be used in the downflow or horizontal orientation
- Can be converted to propane with an LP conversion kit (sold separately)
- Innovative design for electrical efficiency, safety, and lower sound output
Specifications
| SKU | GLXS3BN1810 |
|---|---|
| Weight | 130.000000 |
| Manufacturer | Goodman |
| Replaces | Add GSX130181 and GSXN3N1810 |
| Product Features | New Refrigerant Compliant |
| Cooling BTU | 18,000 |
| Decibel Level (dBA) | 73 |
| Horsepower | 1/8 HP |
| Refrigerant | R32 |
| SEER2 | 13.4 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Max Breaker Size | 15 Amps |
| Min. Breaker Size | 10.9 Amps |
| Tonnage | 1.5 Ton |
| Connection | Sweat |
| Height | 27 1/2" |
| Width | 26" |
| Depth | 26" |
Owner's Manual
- GLXS3B Specifications
- GLXS3B Installation Manual
- Warranty Information
- CHPTA Installation Manual
- CHPTA Specifications Sheet
- Evaporator Coil Warranty
- GCVC96 Installation Manual
- GCVC96 Brochure
- GCVC96 Specifications
What our Experts Think
-
Right‑Sized Cooling & Heating
• 1.5 ton capacity delivers balanced cooling and heating for small living spaces, avoiding oversizing and unnecessary energy waste. -
Energy‑Smart Cooling (13.4 SEER2)
• 13.4 SEER2 offers good summer efficiency and consistent comfort without premium system costs — ideal for everyday use. -
High‑Efficiency Heating (96% AFUE)
• Excellent 96% Annual Fuel Utilization Efficiency helps reduce winter energy expenses by turning most fuel into heat. -
Horizontal Installation Flexibility
• Designed for horizontal airflow applications, which makes it a great fit in attics, crawl spaces, or compact mechanical areas where vertical space is limited. -
Modern R‑32 Refrigerant
• Uses R‑32, a more efficient, lower‑impact refrigerant that supports better system performance versus older options. -
Dependable Goodman Durability
• Built with durable components and accessible service points, this system is practical for long‑term comfort and easier maintenance.
Q&A
Q: What components are included in this HVAC package?
A: A matched set including a 1.5 ton R‑32 air conditioner condenser (GLXS3BN1810), a horizontal evaporator coil (CHPTA2426B3), and a 60,000 BTU 96% AFUE gas furnace (GCVC960603BN) for complete year‑round comfort.
Q: What size home is this system suitable for?
A: The 1.5 ton cooling capacity and 60,000 BTU heating output are ideal for smaller homes or spaces, depending on insulation, climate, and duct design.
Q: How efficient is the cooling component?
A: The air conditioner delivers ~13.4 SEER2 efficiency, balancing energy savings with reliable performance.
Q: What does 96% AFUE mean?
A: 96% AFUE means that 96% of combustion fuel becomes usable heat, reducing fuel waste and lowering heating costs.
Q: What type of furnace performance features are included?
A: The furnace uses a two‑stage burner and variable‑speed blower motor for more consistent comfort and quieter operation.
Q: What refrigerant is used?
A: The system uses R‑32 refrigerant, which offers improved energy efficiency and a lower environmental impact versus older refrigerants.
Q: What installation orientation is supported?
A: Designed for horizontal installation, making it suitable for attics, crawlspaces, or tight mechanical rooms.
Maintenance Tips
-
Replace or Clean Air Filters
Inspect monthly; replace every 1–3 months to maintain airflow and efficiency. -
Clean Condenser and Evaporator Coils
Dirt buildup reduces cooling efficiency; schedule annual professional cleaning. -
Inspect Furnace Burner and Heat Exchanger
Annual inspection ensures safe operation and maintains 96% AFUE efficiency. -
Check Condensate Drain and Pan
Clear blockages to prevent water damage and maintain AC performance. -
Maintain System Clearance
Keep 2–3 ft around indoor and outdoor units free from debris for proper airflow. -
Verify Thermostat and System Operation
Ensure heating and cooling cycles function correctly and thermostat is properly calibrated. -
Schedule Annual Professional Service
Technician should check gas lines, electrical connections, refrigerant levels, and blower operation to extend system lifespan.