Whole‑Home Comfort Package: The Goodman CHPTA3630B3 HVAC System pairs an 80% AFUE gas furnace with a 2.5 ton (60,000 BTU) air conditioner, delivering efficient year‑round heating and cooling in one matched system.
-
Reliable Heating Performance: With 80% AFUE, the gas furnace provides steady warmth and dependable performance for moderate climates and everyday use.
-
Efficient Cooling (14.5 SEER2): The air conditioner helps keep summer energy use lower while maintaining comfortable indoor temperatures.
-
Horizontal Installation Fit: Designed for horizontal duct configurations, making it ideal for crawlspaces, attics, or low‑clearance mechanical areas.
-
R32 Refrigerant Advantage: Uses R32 refrigerant, offering improved heat transfer efficiency and a smaller environmental footprint compared with older refrigerants.
-
Matched System Efficiency: Engineered as a coordinated furnace + AC system to ensure consistent airflow, balanced performance, and reliable seasonal comfort.
-
Goodman Value & Durability: Combines solid heating and cooling efficiency with flexible installation, making it a practical, cost‑effective HVAC solution for many homes.
Goodman - 2.5 Ton/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14.5 SEER2 - R32 - CHPTA3630B3
Goodman - 2.5 Ton/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14.5 SEER2 - R32 - CHPTA3630B3
Couldn't load pickup availability
Goodman - 2.5 Ton/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14.5 SEER2 - R32 - CHPTA3630B3
Goodman - 2.5 Ton/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14.5 SEER2 - R32 - CHPTA3630B3
A Goodman gas furnace and air conditioner system is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, a Goodman gas furnace and air conditioner system is the perfect choice for all of your heating and cooling needs.
Features
- Ideal size to cover a medium-sized house
- 2.5 ton, 13.4 SEER2 AC-only condenser
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Low sound output
- Fully charged for up to 15' of line set
- Factory-installed filter drier
- 2.5 ton horizontal evaporator coil
- Can be used with heat pump and AC-only condensers
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
- Factory-installed TXV kit
- This furnace is ideal to heat a medium-sized house (in average climate conditions)
- 60,000 BTU 80% AFUE two stage variable speed natural gas furnace
- Requires metal flue venting
- Can be used in the upflow or horizontal orientation
- Can be converted to propane with an LP conversion kit (sold separately)
- Innovative design for electrical efficiency, safety, and lower sound output
Specifications
| 2.5 Ton 13.4 SEER2 Goodman Air Conditioner Condenser - R32 | |
|---|---|
| SKU | GLXS3BN3010 |
| Weight | 149.000000 |
| Manufacturer | Goodman |
| Replaces | Add GSX130301 and GSXN3N3010 |
| Product Features | New Refrigerant Compliant |
| Cooling BTU | 30,000 |
| Decibel Level (dBA) | 74 |
| Horsepower | 1/8 HP |
| Refrigerant | R32 |
| SEER2 | 13.4 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Max Breaker Size | 25 Amps |
| Min. Breaker Size | 14.7 Amps |
| Tonnage | 2.5 Ton |
| Connection | Sweat |
| Height | 32 1/2" |
| Width | 26" |
| Depth | 26" |
Manual
- GLXS3B Specifications
-
GLXS3B Installation Manual
- CHPTA Installation Manual
- CHPTA Specifications Sheet
- GMVC80 Installation Manual
- GMVC80 Brochure
What our Experts Think
Q&A
Q: What’s included in this HVAC system?
A: This matched Goodman system includes a 2.5 ton 14.5 SEER2 R32 air conditioner condenser, a 60,000 BTU 80% AFUE gas furnace, and a horizontal cased evaporator coil (CHPTA3630B3) for balanced heating and cooling performance.
Q: What cooling capacity and efficiency does the system provide?
A: The air conditioner delivers 2.5 tons (≈30,000 BTU) of cooling with 14.5 SEER2 efficiency — efficient performance for moderate‑size homes.
Q: What does 80% AFUE mean for heating?
A: 80% AFUE means approximately 80 ¢ of every dollar spent on fuel becomes usable heat, offering reliable heating with standard efficiency and lower fuel costs than older models.
Q: What type of refrigerant does this system use?
A: Uses R32 refrigerant, a modern choice that improves energy performance and meets current environmental standards.
Q: Is this system suited for horizontal installation?
A: Yes — the included CHPTA3630B3 horizontal evaporator coil and furnace are designed for horizontal installation, ideal for tight spaces, attics, closets, or crawlspaces with horizontal duct layouts.
Q: Why choose a matched system over separate components?
A: Matched systems ensure optimized airflow, improved efficiency, consistent performance, and warranty compatibility compared with mismatched parts.
Q: Who is this system best for?
A: Ideal for medium‑sized homes needing balanced year‑round comfort, standard‑efficiency heating, and efficient cooling with modern refrigerant compatibility.
Maintenance Tips
-
Replace Air Filters Regularly: Inspect monthly and replace every 1–3 months to maintain airflow and protect furnace and AC components.
-
Keep Vents & Registers Clear: Ensure supply and return vents are unobstructed for even heating and cooling.
-
Inspect Furnace Venting: Check intake and exhaust pipes for debris or blockages to maintain safe operation.
-
Clean Around the Units: Maintain 2–3 ft clearance around furnace and condenser to prevent dust buildup and allow proper airflow.
-
Check Thermostat & Electricals: Verify thermostat settings, gas supply, and 115V/208–230V circuits for correct operation.
-
Monitor System Performance: Listen for unusual noises from the blower or condenser; reduced heating or cooling efficiency may indicate maintenance needs.
-
Schedule Annual Professional Service: A licensed HVAC technician should inspect burners, heat exchanger, gas pressure, AC refrigerant charge, and safety controls yearly.