Goodman - 2 Ton/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Upflow - 14.5 SEER2 - R32 - CAPTA2422B3
Goodman - 2 Ton/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Upflow - 14.5 SEER2 - R32 - CAPTA2422B3
Couldn't load pickup availability
Goodman - 2 Ton/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Upflow - 14.5 SEER2 - R32 - CAPTA2422B3
Goodman - 2 Ton/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Upflow - 14.5 SEER2 - R32 - CAPTA2422B3
A Goodman combination system is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, a Goodman furnace and air conditioning system is the perfect choice for all of your heating and cooling needs.
Features
- All-Aluminum Coil: Goodman's evaporator coils maximize surface area and optimize heat transfer for efficient comfort by using a reliable all-aluminum design complete with sine fins and grooved tubes.
- Internal Thermostatic Expansion Valve: Goodman's CAPTA units have a factory-installed internal thermostatic expansion valve, which streamlines installation and maintains ideal refrigerant flow for your system.
- Cabinet Durability: Providing superior longevity and efficiency, CAPTA units have a galvanized, embossed, and insulated cabinet that protects the coil and prevents air leakage.
- Condensate Management: Keeping your system sage and operational, the CAPTA units feature a foil-faced insulation to inhibit the formation of condensate and a rust-resistant, DecaBDE-free thermoplastic drain pan secondary drain connections. The drain pan is UV-resistant.
- R32 Compatibility: Complies with Clean Air Act New Refrigerant Requirements.
Specifications
| SKU | GLXS3BN2410 |
|---|---|
| Weight | 130.000000 |
| Manufacturer | Goodman |
| Replaces | Add GSX130241 and GSXN3N2410 |
| Cooling BTU | 24,000 |
| Blower Motor | Single Speed PSC Motor |
| Decibel Level (dBA) | 74 |
| Horsepower | 1/8 HP |
| Refrigerant | R32 |
| SEER2 | 13.4 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Max Breaker Size | 15 Amps |
| Min. Breaker Size | 10.9 Amps |
| Tonnage | 2 Ton |
| Connection | Sweat |
| Height | 27.5" |
| Width | 26" |
| Depth | 26" |
Manual
- GLXS3B Specifications
-
GLXS3B Installation Manual
- Installation Manual
-
CAPTA Specifications Sheet
- GMVC80 Installation Manual
- GMVC80 Brochure
What our Experts Think
-
Efficient Heating & Cooling: 80% AFUE furnace paired with 14.5 SEER2 AC provides year-round comfort and energy savings.
-
Right-Sized System: 2 Ton / 60,000 BTU output suits small to medium homes.
-
Upflow Installation: Designed for easy integration into standard ductwork layouts.
-
Reliable Performance: Engineered for consistent, dependable heating and cooling.
-
Eco-Friendly Refrigerant: AC uses R32 to reduce environmental impact.
-
Durable Build: Built for long-term reliability across diverse climates.
-
Quiet Operation: Optimized for low operational noise in both heating and cooling modes.
Q&A
Q: What’s included in this system?
A: This split HVAC system bundles a Goodman air conditioner condenser, matched cased evaporator coil (CAPTA2422B3), and an 80% AFUE gas furnace — all designed to work together for balanced performance and efficiency.
Q: What cooling capacity does it deliver?
A: The outdoor AC condenser delivers 24,000 BTU (2 tons) of cooling with a 14.5 SEER2 efficiency rating for reliable, seasonal comfort.
Q: What heating performance can I expect?
A: The matched gas furnace provides 60,000 BTU of heating at 80% AFUE, ideal for small to medium‑sized homes in many climates.
Q: What refrigerant does the system use?
A: This system uses R‑32 refrigerant, a newer, more environmentally responsible option with lower global warming potential compared with many older refrigerants.
Q: What blower and airflow features are included?
A: The furnace includes a multi‑speed blower motor for smoother airflow and quieter operation.
Q: What installation configuration does it support?
A: Designed for upflow installation, with many systems also adaptable to horizontal configurations when paired with proper ductwork.
Q: Is this system certified for performance and safety?
A: Yes — the components are AHRI‑certified and ETL‑listed to meet performance and safety standards.
Maintenance Tips
-
Replace air filters every 1–3 months to maintain airflow and system efficiency.
-
Keep supply and return vents clear of furniture, dust, and debris.
-
Maintain 2–3 feet of clearance around the furnace and condenser for safe operation.
-
Inspect the condensate drain line periodically to prevent clogs and water damage.
-
Check thermostat settings and operation for proper heating and cooling cycles.
-
Examine vent pipes, ductwork, and connections for leaks or blockages.
-
Clean blower compartment and indoor coil surfaces to reduce dust buildup.
-
Inspect the outdoor air conditioner coil regularly and remove debris to maintain efficiency.
-
Listen for unusual noises such as rattling, buzzing, or humming indicating potential mechanical issues.
-
Schedule annual professional HVAC maintenance to inspect burners, heat exchanger, refrigerant levels, and electrical components.