Imer R-Series Stators and Rotors for Koine Pumps - 1107624
Imer R-Series Stators and Rotors for Koine Pumps - 1107624
Couldn't load pickup availability
Imer R-Series Stators and Rotors for Koine Pumps - 1107624
Imer R-Series Stators and Rotors for Koine Pumps - 1107624
If you're in need of a high-quality replacement and repair part for your Imer USA equipment, look no further. The stator clamps and rotors with tab are designed to provide reliable and long-lasting performance, ensuring that your equipment continues to operate at its best. With its durable construction and precise engineering, this stator is a smart investment for anyone looking to keep their Imer USA equipment in top condition.
Designed for easy installation and a perfect fit, they are a cost-effective solution for your repair needs. With a focus on quality and performance, this stator is sure to exceed your expectations. Don't settle for subpar replacement parts - trust in the reliability and durability of Imer for all your repair and maintenance needs.
Features
- R7 - 1.5 is ideal for Koine 4 Hi-Flow & DUAL
-
R7 - 2.5 is ideal for Koine DUAL
- R8 - 1.5 is required for Koine 4 Hi-Flow & DUAL
- Direct fit for easy installation
- Durable construction for long-lasting performance
- Manufactured to meet or exceed OEM specifications
What our Experts Think
-
Critical wear component for Koine pump systems
The IMER R-Series Stator & Rotor (Ref. 1107624) is a core pumping element used inside Koine continuous mixing and pumping machines, responsible for moving and pressurizing material through the system. -
Engineered for high-flow screed and grout applications
The R7-1.5 stator is optimized for self-leveling screeds, injection mortars, structural repair materials, and grouts, ensuring stable flow and consistent output on professional jobs. -
Matched rotor–stator precision system
Works as a paired assembly (stator + rotor with tab), designed to maintain correct compression and pumping efficiency inside Koine 4 systems. -
Designed for demanding continuous operation
Built for high-duty cycles in job-site pumping, where consistent pressure and wear resistance are essential for uninterrupted material flow. -
Supports high-volume material movement
Ideal for cementitious, anhydrite, and reinforcement mortars, making it a key consumable in large-scale flooring and construction pumping work. -
Service-critical replacement part
This is a wear item, not an accessory, meaning performance of the Koine pump directly depends on timely replacement to maintain output quality and pressure stability.
Q&A
Q1: What is the Imer 1107624 R-Series Stator used for?
A: The 1107624 is an R7-1.5 stator (mustard type) used in IMER Koine continuous mixing and pumping systems, designed for spraying and pumping construction mortars.
Q2: What equipment is it compatible with?
A: It is designed for IMER Koine 4 Hi-Flow and Koine Dual pumps, working as part of the rotor-stator pumping system for continuous material flow.
Q3: What does a rotor-stator do in these pumps?
A: The rotor and stator work together to mix, pressurize, and push materials through hoses, ensuring a consistent flow of mortar, grout, or coating materials.
Q4: What materials can it handle?
A: It is used for self-leveling screeds, grouts, waterproofing mortars, fireproofing materials, and structural repair mortars.
Q5: What is the performance capacity?
A: The R7-1.5 system supports high-flow pumping (around 60 L/min at 400 RPM depending on setup) for continuous professional spraying applications.
Q6: What is included in the R-Series system?
A: It typically includes a matched stator (1107624) and rotor (1107664 or equivalent), designed to work together for proper pressure and flow balance.
Q7: Why is rotor-stator condition important?
A: Wear affects pressure, flow consistency, and spraying quality, so replacing both components together maintains optimal pump performance.
Q8: Is it a consumable part?
A: Yes, rotor-stator sets are wear parts that must be replaced periodically depending on material abrasiveness and usage intensity.
Maintenance Tips
- Flush immediately after use: Clean pump, hoses, and stator/rotor with water until discharge runs clear to prevent hardened mortar buildup.
- Never let material dry inside: Even small residue can damage sealing surfaces and reduce pumping efficiency.
- Inspect wear regularly: Check stator rubber and rotor edges for swelling, cuts, or wear—replace when output becomes uneven or pulsating.
- Use correct lubrication only: Apply IMER-approved stator lubricant during assembly; avoid grease, mineral oil, or benzene as they can damage components.
- Check alignment & coupling: Ensure rotor is properly seated inside the stator to avoid premature wear and pressure loss.
- Maintain clean seals & hoses: Air leaks reduce pressure and increase strain on the R-series set.
- Avoid dry running: Running without material causes rapid overheating and permanent stator damage.
- Store dry & protected: Keep stator/rotor clean, dry, and away from UV or heat to preserve rubber elasticity.
- Routine inspection schedule: Periodically inspect during service intervals to maintain consistent flow and pumping pressure.
