Mölnlycke Z-Flo - Pediatric Fluidized Positioner Kit Various Dimensions Floam Freestanding - 1400403
Mölnlycke Z-Flo - Pediatric Fluidized Positioner Kit Various Dimensions Floam Freestanding - 1400403
Couldn't load pickup availability
Mölnlycke Z-Flo - Pediatric Fluidized Positioner Kit Various Dimensions Floam Freestanding - 1400403
Mölnlycke Z-Flo - Pediatric Fluidized Positioner Kit Various Dimensions Floam Freestanding - 1400403
- Z-Flo positioners can be used to help protect the occiput by providing pressure redistribution while maintaining proper head and neck alignment
- Mölnlycke Z-Flo Fluidized Positioners offer the ability to uniquely conform to and support the patient’s body in a comfortable position until time to reposition again
Specifications
Stock Number : 1093010
Manufacturer # : 1400403
Brand : Mölnlycke Z-Flo
Manufacturer : Molnlycke
Country of Origin : United States
Application : Pediatric Fluidized Positioner Kit
Color : Beige
Cover Material : With Cover
Dimensions : Various Dimensions
Inflation Type : Noninflatable
Material : Floam
Size : Medium
UNSPSC Code : 42211503
What our Experts Think
- Pediatric fluidized positioning kit designed to provide gentle, stable, and pressure-redistributing support for children in clinical care.
- Floam technology conforms precisely to body contours, helping reduce localized pressure and improve comfort during treatment or recovery.
- Freestanding, moldable design allows clinicians to shape and reposition support for individualized pediatric needs.
- Helps maintain safe alignment and controlled positioning during procedures, imaging, or extended care.
- Consistent support structure reduces the need for frequent adjustments once properly molded.
- Supports pressure injury prevention strategies in vulnerable pediatric patients with limited mobility.
- Lightweight and adaptable, making it practical for repeated clinical use across different care environments.
- A specialized hospital-grade solution intended for professional pediatric healthcare teams.
Q&A
Q: What is the Mölnlycke Z-Flo Pediatric Fluidized Positioner Kit (1400403) used for?
A: A neonatal and pediatric fluidized positioning system designed for hospitals to support safe positioning, pressure redistribution, and comfort for infants and children in clinical care settings.
Q: What is included in the 1400403 kit?
A: It is a multi-piece pediatric kit that typically includes fluidized positioners in different sizes along with covers and securing straps, allowing customized positioning setups for NICU and pediatric patients.
Q: How does the Z-Flo pediatric system work?
A: It uses a fluidized medium of microspheres and viscous fluid inside a flexible outer film that molds to the patient’s body and maintains its shape until remolded, creating stable “nest-like” support.
Q: What is it used for in pediatric care?
A: It helps maintain optimal body alignment, reduce pressure on sensitive areas, and support positioning for fragile neonates or children during treatment, rest, or procedures in NICU/paediatric units.
Q: Can it be reshaped during treatment?
A: Yes. It can be manually remolded multiple times to adjust positioning as the patient’s clinical needs change.
Q: Who is this product intended for?
A: It is intended strictly for use by trained healthcare professionals in neonatal intensive care and pediatric hospital environments, not for home use.
Maintenance Tips
- Inspect cover before each use for tears, seam damage, or bead leakage; do not use if compromised.
- Ensure fluidized beads are evenly distributed before positioning to maintain consistent pressure support.
- Clean outer cover using approved hospital-grade disinfectants per facility infection-control protocols.
- Do not immerse internal bead system unless specifically approved by manufacturer instructions.
- Allow full air drying after cleaning to prevent moisture retention and microbial growth.
- Avoid exposure to sharp instruments, excessive heat, or autoclaving, which can damage the structure.
- Store flat in a clean, dry clinical area away from direct sunlight and contamination sources.
- Replace if support becomes uneven, compressed, or no longer maintains proper fluidization performance.
